Our mission is usually to turn into an innovative provider of high-tech digital and communication devices by providing worth added design and style, world-class producing, and repair capabilities for Outdoor Network Enclosure Box , Rmu Electrical , Stage Power Distribution Box , With a rapid advancement and our buyers come from Europe, United States, Africa and everywhere in the world. Welcome to visit our manufacturing unit and welcome your order, for further more inquires be sure to don't hesitate to get hold of us!
High Quality Ggd Low Voltage Switchgear - GGJ low voltage reactive power intelligent compensation device – AGP Electrical Detail:

Overview

GGJ low voltage reactive power intelligent compensation device adopts computer aided design (CAD), introduces microcomputer control, and carries out intelligent tracking compensation for reactive power quantity. its structure is reasonable, the technology is first applied, and it is widely used in low voltage power grid to improve power factor, reduce reactive power loss and improve power supply quality. reactive power compensation for 130-600 KVA three-phase transformers.

Model meaning

GGJ

Use of environmental conditions

♦ altitude: w 2000m;
♦ ambient temperature :-20 fence ~+45 C;
♦ relative humidity: W90%; at 20 C
♦ installation environment: no harmful gas and steam, no conductive or explosive dust particles and serious mold.

Main features

♦ Adopt intelligent controller control, complete functions, reliable performance, automatic compensation mode: can increase the power factor to more than 0.9:
♦ Real-time display of grid power factor, display range: lag (0.00-0.99), lead (0.00-0.99):
♦ It has multiple comprehensive protection functions such as over-voltage, over-harmonic, over-compensation, system failure, phase loss, overload, etc.;
♦ Remember the set parameters, and the system will not lose the parameters after power failure. After the power grid returns to normal, it will automatically enter the running state without personnel on duty:
♦ According to the load balance of the power grid, split-phase compensation or mixed compensation can be adopted;
♦ Strong anti-interference ability, able to resist 2000V interference pulses directly input from the power grid, which is higher than the national professional standards. 

Main technical parameters

♦ Rated voltage: 0.38-0.66kV;
♦ Rated frequency: 50Hz;
♦ Rated capacity: 1-600kvar;
♦ Applicable voltage range: (0.85-1.1) times rated voltage;
♦ Maximum allowable current: 1.3 times rated current;
♦ Control circuit: 1-1 6 circuit;
♦ Switching time: 1-150S/time, adjustable;
♦ Working mode: automatic, continuous operation.

Detection of Distribution Grid

♦ Real-time measurement and whole-point recording of the three-phase voltage, current, frequency, active power, reactive power, power factor, active power, and reactive power of the low-voltage side of the transformer: total distortion rate of voltage and current and 2-25th harmonic content;
♦ It has RS-232 and RS-485 interfaces, which can be used to copy data from the handheld computer, and can also realize wireless meter reading, device testing, parameter setting, and reading of real-time measurement data and record data through the remote communication function;
♦ Data analysis function: It can analyze and process the running load data and statistical query; comprehensively analyze the power supply quality, calculate the voltage qualification rate, power supply load rate, reliability rate and maximum load rate; query the power factor, active power and reactive power by period ; Draw the voltage, current, power factor and other curves of each phase: print comprehensive analysis and statistical reports.

Dimensions and installation

GGJ 01

Examples of Device System Principles

GGJ 02

Order Notes

1. Main circuit scheme diagram;
2. Compensation capacity and compensation method;
3. If it does not conform to the normal use conditions of the product, it must be explained in advance.


Product detail pictures:

High Quality Ggd Low Voltage Switchgear - GGJ low voltage reactive power intelligent compensation device – AGP Electrical detail pictures


Related Product Guide:

We're committed to providing easy,time-saving and money-saving one-stop purchasing service of consumer for High Quality Ggd Low Voltage Switchgear - GGJ low voltage reactive power intelligent compensation device – AGP Electrical , The product will supply to all over the world, such as: Adelaide, Mauritius, Rwanda, We now have been making our goods for more than 20 years . Mainly do wholesale , so we've the most competitive price , but highest quality. For the past years , we got very good feedbacks , not only because we offer good solutions , but also because of our good after-sale service . We are here waiting for yourself for your inquiry.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Roxanne from Madagascar - 2017.09.30 16:36
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Agustin from Colombia - 2018.12.22 12:52
    Write your message here and send it to us